Integrated Wastewater

WSZ is an integrated sewage treatment equipment

Date:2017-03-21 15:30:52 From: Browse times:
               Characteristic:
        1, the equipment can be buried, buried, or placed above the surface, can not be arranged in accordance with the standard form, and according to the terrain needs to set.
        2, set up the basic equipment for buried surface area, without heating and heat preservation facilities can be built green, parking, road etc..
        3, the use of micro channel aeration system engineering Co., Ltd. Germany membrane gas pipeline production of oxygen, no blockage, high oxygen efficiency, good aeration effect, energy saving.
        4, the use of integrated design, small footprint, low investment, low operating costs, equipped with automatic control system.
        5, new technology, good effect, less sludge, easy operation and maintenance, low noise, long service life, continuous operation for more than 10 years.
        Application and introduction:
        Suitable for hotels, restaurants, nursing homes, hospitals, schools, shopping malls, residential areas, villages and towns, the ship docks, stations, airports, factories, mines, tourist attractions, scenic spots such as sewage treatment or sewage similar industrial organic wastewater treatment.
        Structure principle:
        All the facilities of WSZ-F equipment are set up in a number of box body, box according to the needs of the user material, each box with (stainless) steel pipe or ABS pipe connection, and the use of chemical products recommended by the Ministry of chlorosulfonated polyethylene anti-corrosion coatings, anti-corrosive effect can reach more than ten years.
        WSZ-F type equipment is mainly used for the treatment of domestic sewage and similar industrial organic wastewater.
        Process flow chart:
        Main technical parameters:
Model   WSZ
    0.5 1 3 5 10 20 30
Treatment capacity(㎡/h)   0.5 1 3 5 10 20 30
Fan Model `GHBH0D512/R2 GHBH0D512/R2 GHBH1D712/R4 GHBH1D712/R4 GHBH5D736/R8 GHBH5D736/R8 GHBH5D536/R8
For reference only power(kw) 0.55 0.55 1.5 1.5 4 4*2 5.5*2
Water pump 型号 AS10-2CB AS10-2CB AS10-2CB AS10-2CB AS10-2CB AS16-2CB AS16-2CB
For reference only power(kw) 1.1 1.1 1.1 1.1 1.1 1.1 1.1
inlet BODsmg/L 150-400 150-400 150-400 150-400 150-400 150-400 150-400
effluent BODsmg/L 20-30 20-30 20-30 20-30 20-30 20-30 20-30
Equipment size(mm) H 1500 1900 2400 2700 2600 2700 3000
  H1 1000 1300 1800 2100 1800 1900 2100
  H2 1000 1300 1700 2100 1900 2100 2300
  Dn1 80 80 80 80 100 100 100
  Dn2 80 80 100 100 100 125 125
 Table 1 BODs relationship between WZS and water:   
inletBODs(mg/L)   200 300 400 200 300 400 500 300 400 500
effluentBODs(mg/L)   20 20 20 30 30 30 30 60 60 60
Treated water(㎡/h) BFWSZ-0.5 0.5 0.4 0.33 0.5 0.4 0.38 0.3 0.5 0.48 0.38
BFWSZ-1 1 0.8 0.65 0.1 0.9 0.75 0.6 1 0.85 0.75
BFWSZ-3 3 2.4 1.95 3 2.7 2.25 1.8 3 2.55 2.25
BFWSZ-5 5 4 3.25 5 4.5 3.75 3 5 4.25 3.75
BFWSZ-10 10 8 6.5 10 9 7.5 9 10 8.5 7.5
BFWSZ-20 20 16 13 20 18 15 15 20 17 15
BFWSZ-30 30 24 19.5 30 27 22.5 22.5 30 25.5 25.5


      WZS equipment layout plan:
        Ordering instructions:
        References material structure is as follows, please select the user
        Stainless steel structure
        Q235A steel plate and glass fiber reinforced plastic composite structure
        Reinforced concrete structure
        Q235A steel plate structure
        FRP structure
        PVC full plastic structure
        To ensure the effectiveness of the equipment in the actual application, please provide the following data:
        1 treatment of water, raw water quality and water requirements;
        2 set the conditions of the equipment, the water inlet and outlet pipe set, etc.;
        3 other special requirements.
 

 